CHRONOTHERMOSTAT
to the time interval selected. To complete the change,
press ENTER. It is immediately possible to decide
whether to apply the same programming to the follow-
ing 24 hours. To extend it by one day, respond to the
system prompt by selecting
peat the operation until a typical week has been defined.
Summer adjustment - Weekly Schedule
[ MENU
SUMMER ADJUSTMENT ]
à
à
SETTINGS
When the SUMMER mode is enabled, access
justment
(*) to define the weekly schedule. Refer to the
similar procedure, described in the previous paragraph
(Zones).
Manual for 1 hour and then Auto (Manual Mode)
[ MENU
à
à
à
MODE
MAN. MODE
[ MENU
à
à
à
MODE
MAN. MODE
Access the
Manual Mode
1 hour and then
auto, using the
temporarily activate this mode, and then press ENTER.
Alternatively, select
Man. for two hours and then auto
Set duration of manual mode
Then press ENTER. In the second case, to set this dura-
tion, use the
Up/down
arrows and define the required
period of time. Then press
If you want to specify a period longer than 24 hours, the
system automatically switches to count days.
NOTE: using this mode, for example, it is possible to
manage the plant during a holiday period. In fact,
proper program setting, ensures an anticipated return
to conditions of comfort with respect to the scheduled
date of return from the holiday.
Shutdown for 1 hour and Auto (OFF Mode)
[ MENU
à
à
à
MODE
OFF MODE
Access the
OFF mode
section and follow the same pro-
cedure (See previous paragraph).
* ATTENTION: in 'Summer adjustment' selecting the zones is not necessary. In Summer mode the system operates in ON/OFF mode
on all the actuators and on a single zone, whose temperature is measured directly by the chronothermostat. It is possible to disable
the summer operation of one or more of the actuators (See Anti-condensation function adjustment on pg. 23).
ENTER
and then EDIT. Re-
Summer Ad-
MANUAL FOR 1 HOUR... ]
MANUAL FOR 2 HOURS... ]
section and select
Man. for
Up/down
arrows, to
to define longer durations.
ENTER
to complete.
SWITCH OFF FOR... ]
[10]
300546US-10-14
INSTALLING THE CHRONOTHERMOSTAT
Follow the instructions below to operate device:
1)
Choose a location for the device and mount it on the wall.
2)
Insert the batteries.
3)
Associate each actuator to the chronothermostat,
defining the various zones of the building. (See the
paragraph, 'Association of an actuator with the chrono-
thermostat' on pg. 19).
Typical placement of device
The chronothermostat measures the temperature of
the room where it is installed; therefore, it must be in
a position exposed to good air circulation, at 5 ft above
the floor.
The following instructions must be followed.
• DO NOT place near a radiator.
• DO NOT place near doors.
• DO NOT place on perimeter walls.
or
• DO NOT place in correspondence to piping inside the walls.
• DO NOT place in rooms with exceptional temperature
and humidity conditions (For example the kitchen
and bathroom).
• DO NOT place where the device may come into con-
tact with water.
• DO NOT expose to direct sunlight.
NOTE: when placing the thermostat, it is necessary to
verify that the actuators are located within a certain
range. In ideal conditions - without any obstacles - this
range covers 33 yd. Among the factors that can affect
transmission performance, humidity and the architec-
tural features of the building must be considered.
1 ft
5 ft