Description / Typical Installation
PENTEK INTELLIDRIVE Includes:
• PENTEK INTELLIDRIVE
• Pressure Transducer
• 10' Pressure Transducer Cable
• Quick Start Guide
• Owner's Manual
The PENTEK INTELLIDRIVE is specifically designed to
operate 4" submersible pumps and 3-phase above
ground pumps in water well and residential booster
applications. Each drive is rated for maximum output
amp rating. Any use of the drive outside of its intended
use and design parameters will void the warranty. If the
PENTEK INTELLIDRIVE is used with above ground
motors not rated for VFD use, limit lead length to 25 ft.
for maximum motor life. Refer to the pump owner's
manual and the National Electrical Code for proper
wire size.
Transducer
The drive uses a 4-20mA, 0-100PSI pressure transducer to
control the speed of the motor.
The transducer senses pressure in the pipe and converts it
to an electrical signal which it sends to the drive. The drive
processes the signal in the PID (Proportional, Integration,
Derivative) control. When operating in PID mode the drive
increases and decreases the speed of the pump motor as
needed to maintain constant pressure in the system.
Figure 1: Overall Layout – Typical installation
TM
Grnd
Table 1: Model Number Structure
PID-1- 10A1-1:
PID
–
1
Product Family
PID = Pentek IntelliDrive
Voltage Rating:
1 = 190–265 Volt 1-Ph. In,
3-Phase Out
6 = 190–265 Volt 1-Ph. In,
1-Phase Out
Max Amp Rating:
4A7 = 4.7 Amps
7A6 = 7.6 Amps
9A7 = 9.7 Amps
10A1 = 10.1 Amps
12A2 = 12.2 Amps
Fan
The PENTEK INTELLIDRIVE has a thermostatically con-
trolled internal fan. The fan may not operate under normal
operating conditions. It will automatically start when nec-
essary to cool the drive.
Keypad
The Keypad programs the drive, monitors the status of the
pump, and views faults if they occur. Each button has a
unique function (see Page 5). The LCD display shows a
text display of the status of the drive's operation. Other
LEDs light up to indicate when certain buttons are pressed
or certain events occur.
–
10A1 – 1 –
Enclosure Type:
1 = NEMA 1 (Indoor Rated)
3 = NEMA 3R (Outdoor Rated)
Revision Code:
Transducer; install in straight
pipe at least one foot away from
pipe fittings on each side.