DOUBLE INSULATION

Double insulation is a concept in safety in electric power
tools, which eliminates the need for the usual three-
wire grounded power cord. All exposed metal parts are
isolated from the internal metal motor components with
protecting insulation. Double insulated products do not need
to be grounded.
WARNING:
The double insulated system is intended to protect the
user from shock resulting from a break in the product's
internal insulation. Observe all normal safety precautions
to avoid electrical shock.
NOTE: Servicing of a product with double insulation requires
extreme care and knowledge of the system and should be
performed only by a qualified service technician. For service,
we suggest you return the product to your nearest authorized
service center for repair. Always use original factory replace-
ment parts when servicing.

ELECTRICAL CONNECTION

This product has a precision-built electric motor. It should
be connected to a power supply that is 120 volts, AC only
(normal household current), 60 Hz. Do not operate this
product on direct current (DC). A substantial voltage drop
will cause a loss of power and the motor will overheat. If
the product does not operate when plugged into an outlet,
double-check the power supply.
EXTENSION CORDS
When using a power tool at a considerable distance from
a power source, be sure to use an extension cord that has
the capacity to handle the current the product will draw. An
undersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter's Laboratories
(UL) should be used.
When working outdoors with a product, use an extension
cord that is designed for outside use. This type of cord is
designated with "WA" or "W" on the cord's jacket.
Before using any extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
It is possible to tie the extension cord and power cord in a
knot to prevent them from becoming disconnected during use.
Make a knot, then connect the plug end of the power cord
into the receptacle end of the extension cord. This method
can also be used to tie two extension cords together.

ELECTRICAL

**Ampere rating (on product data plate)
Cord Length
25'
50'
100'
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on
lumber, tools, or other obstructions while you are working
with a power tool. Failure to do so can result in serious
personal injury.
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use the product with a
damaged cord since touching the damaged area could
cause electrical shock resulting in serious injury.

GROUND FAULT CIRCUIT INTERRUPTER

See Figure 2.
The Ground Fault Circuit Interrupter (GFCI) on this unit will
reset to ON when plugged in. In the event of a ground fault,
press the RESET button to restore power.
This GFCI guards against the hazards of ground fault cur-
rents. An example of ground fault current is the current that
would flow through a person who is using an appliance
with faulty insulation and, at the same time, is in contact
with an electrical ground such as a plumbing fixture, wet
floor, or earth.
GFCI plugs do not protect against short circuits, overloads,
or shocks.
NOTE: To ensure readiness for use, press the TEST button
each time you connect the pressure washer to the power
supply.
To test:
 Depress the TEST button. This should cause the RESET
button to pop out.
 To restore power, depress the RESET button.
Perform this test monthly to ensure proper operation of the
GFCI.
Page 8 — English
0-2.0
2.1-3.4
3.5-5.0
5.1-7.0
Wire Size (A.W.G.)
16
16
16
16
16
16
16
16
14
7.1-12.0 12.1-16.0
16
14
14
14
14
12
12
10

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido