3. Separate the drum front from the drum back by hold-
ing the drum back and twisting the drum front counter
clockwise. (Figure 14) .
Figure 14 – Twist Drum Apart
4. Remove the inner drum out of the drum back. Pull
cable back through drum front. With the AUTO FEED
both levers will need to be pulled up to allow the
bulb of the auger to pass through.
5. Reverse process to install inner drum. Inspect con-
dition of gasket on drum front and replace if neces-
sary. This prevents liquid leakage from drum.
Loading Cable Into Inner Drum
1. Remove existing cable from drum if required.
2. To make installing the new cable easier, completely
uncoil the new cable before proceeding. Use caution
when removing the cable from the package. The
cable is under tension and could strike the user.
3. Add a 15 - 30 degree bend approximately 1" (25.4mm)
from the drum end of the cable as shown in Figure 15 .
Figure 15 – Bend At Cable End
4. Coil the cable into the inner drum CLOCKWISE (See
Figure 16) .