Troubleshooting
Problem
Cause
Status LED
eStore is configured to be con-
flashes red.
nected to multiple eStores and
BUS cables are not plugged
in.
eStore is over discharged.
eStore is over charged
eStore ist defective.
eStore does not
eStore is in storage mode.
respond to
eStore is over discharged.
pressing of the
main switch
command.
eStore is configured as slave
and not as master.
Configuration for connecting
multiple eStores is faulty.
eStore is defective.
26
Remedy
➤ Plug in eStore cables.
➤ Charge eStore.
➤ Disconnect chargers from
eStore.
➤ Check the charging voltage
of battery chargers.
➤ Contact an authorised work-
shop.
➤ Activate eStore.
➤ Charge eStore with a charg-
ing current of < 10 A.
Note: Do not use intelligent
charging systems (with main
swtich open, the eStore ter-
minals have no voltage.
Some intelligent battery
chargers do not start if no
voltage is present).
➤ Contact an authorised work-
shop.
➤ Use main switch command
on master eStore (eStore
configured #1)
➤ Check the configuration.
➤ Contact an authorised work-
shop.
eStore