Fig. 4.28
Connection of pneumatic hoses to the Panel
Fig. 4.29
Drill two holes Ø 10 mm (0.4 in.) in the extraction duct at
the indicated positions (A+B).
Connect the pneumatic hose (D) with T-connector (C) to
the extraction duct with the supplied connection material.
A+B
A
B
90°
C
Fig. 4.29 Connection of the pneumatic hose to the extraction duct
5

coMMiSSioNiNg

5.1
general
Make sure that the Panel is connected to the mains.
Turn the main switch (refer to Fig. 6.1E) to "on". The
system will start up
.
34
The HMI starts the installation wizard.
Complete the installation wizard.
Select the question mark on the touch
screen for extensive explanation on all
settings.
5.2

Functional tests

5.2.1
Extraction fan
Push the START/STOP FAN button (refer to Fig. 6.1F) to
start the fan.
Push the button again to stop the fan.
34. Indication: the white LED on the Panel is blinking
0000112606/200917/0 ControlPro
A
Fan Pressure
B
Filter Pressure
A+B
B
D
Panel
?
If any problems or errors occur, refer to chapter 8 /
Troubleshooting.
6

uSE

6.1

Control panel

6.1.1
Panel
The control panel contains the following controls and
indicators:
Fig. 6.1 (also refer to Fig. V on page 83)
A
White LED | POWER ON
- LED off: system is off
- LED blinking: system is starting up
- LED on: system is ready
B
Green LED | FAN RUNNING
- LED off: fan is off
- LED blinking: fan is ramping down
- LED on: fan is running
C
Yellow LED | WARNING
- LED off: no problem
- LED on
: refer to the HMI for the cause of the warning
36
D Red LED | ALARM
- LED off: no problem
- LED on
: refer to the HMI for the cause of the alarm
37
E
Main switch
F
Green button | START/STOP FAN
G Black button | FILTER CLEANING
- to activate an additional filter cleaning cycle
- to suppress the buzzer (push and hold for 5 seconds)
H Rotary switch 0-1 | SERVICE MODE
- 0: normal mode
- I: to lock the touch screen of the HMI for service
purposes
I
Buzzer | acoustic signal
- together with the ALARM signal (D)
- in some cases: together with the WARNING signal (C)
C
D
Panel
E
Fig. 6.1
Control panel
35. Ramp down time: 60 seconds
36. The system continues to run
37. The system stops running
35
A
B
C
D
F
G
H
I
EN - 15