6.2
use
6.2.1
Panel
Depending on the specific configuration and system settings
on the HMI, you can activate the fan and cleaning system
manually or have the entire system run fully automatically.
Manually activated functions:
Fig. 6.1
- green button START/STOP FAN (F)
- black button FILTER CLEANING (G)
You can activate START/STOP FAN and FILTER
CLEANING on the HMI as well.
To suppress the buzzer (I) in case of a WARNING signal (C),
push and hold the black button (G) for 5 seconds
6.2.2
HMI
The HMI shows the actual system status at all times.
If desired, you can activate the fan and the filter cleaning
system manually.
Refer to the online user manual ControlPro for
extensive explanation:
www.plymovent.com/manuals/controlpro
ControlPro/HMI
EN
User manual
NL
Gebruikershandleiding
DE
Betriebsanleitung
FR
Manuel opérateur
ES
Instrucciones para el uso
www.plymovent.com/manuals/controlpro
7
MaiNtENaNcE
7.1
periodic maintenance
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore, we
recommend to thoroughly inspect the complete system once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
WaRNiNg
If applicable, put the Panel in the Service Mode
before you do the activities as stated below; refer to
Fig. 6.1H.
38. You cannot stop/interrupt the filter cleaning cycle
39. You cannot activate this button during the first 40 running hours of the system
and within 40 running hours after filter replacement, to maintain the protective
layer of precoat material on the filter cartridges
40. You must still solve the cause of the warning
0000112606/200917/0 ControlPro
38 39
.
40
Component
action
Panel
Clean the outside with a
non-aggressive detergent
Make sure that the cable
glands are correctly tightened
Make sure that all detachable
screw terminal blocks on the
PC board are connected
HMI
Clean with a non-aggressive
detergent
Make sure that the HMI cable
is connected
Check for firmware updates;
refer to the online user
manual
For maintenance of the connected filter system, fan and
other components, refer to the corresponding manuals.
8
tRouBLEShootiNg
If the system does not function (correctly), consult the
checklist below to see if you can remedy the error yourself.
Should this not be possible, contact your supplier.
WaRNiNg
If applicable, put the Panel in the Service Mode
before you do the activities as stated below; refer to
Fig. 6.1H.
Symptom
problem
panel
Yellow
Refer to HMI
WARNING
LED is on
(with or
without
buzzer)
Red ALARM
Fan stops
LED is on +
Filter cleaning
buzzer
stops
hMi
HMI screen is
No control on
locked
HMI possible
Black screen
HMI does not
function
No
Configuration
installation
of the system
wizard at
not possible
start up
System does
System does
not start
not function
(white LED is
off)
Frequency:
every X months
X=3
X
X
X
X
X
possible
Solution
cause
Refer to HMI;
Refer to HMI
for more info,
refer to the
online user
manual
Panel is in
Put the rotary
service mode
switch on the Panel
to 0 (refer to Fig.
6.1H)
Loose
Tighten the HMI
connection
cable to the CAN
connector (refer to
Fig. 4.7B+C)
Loose or
Connect the HMI
incorrectly
cable to the CAN
connected cable
HMI connector
(refer to Fig. 4.10)
System
Direct to screen 5.8
configured in
to restart the
an earlier stage
wizard manually
If necessary: reset
PIN (refer to online
user manual)
No mains
Connect the mains
voltage
voltages
Main switch is
Turn the main
off
switch to on (refer
to Fig. 6.1E)
X=12
X