WARNING! Risk of personal injury
Use necessary personal safety equipment
when replacing the filter cartridges.
Change the filter cartridge in the following way:
1
Disconnect the mains connection cable.
2
Unlock the eccentric locks and remove the filter
casing.
3
Use the plastic bag which comes with the new fil-
ter cartridge and pull it over the used cartridge.
Fold the plastic bag under the cartridge.
4 Use a duster to wipe off the filter cartridge con-
tact surfaces in the FilterCart W3. Put the duster in
the plastic bag with the filter cartridge and close
the bag with the band supplied.
5
Handle the used filter cartridge according to the
relevant regulations for the substances that have
been collected.
6
Check that the pressure drop hose (from the con-
trol board) not is damaged and is fitted properly.
7
Check that the new filter cartridge is not damaged.
Also, check that the seal fitted on the underside
of the cartridge is not damaged. Then fit the cart-
ridge on the FilterCart W3.
8 Refit the filter casing. Make sure the eccentric
locks tighten the filter casing properly.
• A. Increasing the locking power.
• B. Decreasing the locking power.
10 Changing the HEPA-filter (access-
ory)
See Figure 8. If the FilterCart W3 has been supplied
with a HEPA-filter, this is to be changed at the same
time as the main filter cartridge is changed.
WARNING! Risk of personal injury
Use necessary personal safety equipment
when changing the HEPA-filter.
Change the HEPA-filter cartridge in the following way:
1
Disconnect the mains connection cable.
2
Unscrew the top cover.
3
Remove the used HEPA-filter and put it in the
plastic bag which comes with the new HEPA filter.
Close the plastic bag with the band supplied.
4 Handle the used HEPA-filter according to the rel-
evant regulations for the substances that have
been collected.
5
Check that the new HEPA-filter not is damaged.
Note that the filter surface must not be touched.
Handle the HEPA-filter very carefully and fit it in
the FilterCart W3. Ensure it is fitted in the correct
position and that the seal is downwards. Check
that the seal not is damaged. Note the UP-arrows.
6
Refit the top cover. Fasten it securely.
FilterCart W3
11 Maintenance
See Figure 9. Maintenance is recommended at least
once a year.
WARNING! Risk of personal injury
• Disconnect the mains connection cable be-
fore starting any maintenance work.
• Use the necessary personal safety equip-
ment.
• FilterCart W3 needs to be cleaned before any
disassembly.
• FilterCart W3 must only be disassembled in a
well-ventilated room.
• Use proper equipment, such as a vacuum
cleaner to clean FilterCart W3.
• The area where maintenance is done must be
properly cleaned after work is complete.
Do as follows:
• Change the filter cartridge (and optional HEPA-fil-
ter) if necessary, see
cartridge
• Check that the Fume Extractor hose is not damaged.
If necessary change the hose.
• Check that the hose to the fan inlet is not damaged.
If necessary change the hose.
• Check that no objects have been caught on the
guard net on the fan inlet.
• Check that the pressure drop hose (from the control
board) not is damaged and is fitted properly.
• If necessary, adjust the Fume Extractor links.
• If necessary, tighten the arm profile bolts, see the *
symbols in Figure 9.
• Check that the mains connection cable and the fan
motor cable are not worn out or damaged.
• Check that the eccentric locks tighten the filter cas-
ing properly. Adjust the eccentric locks if necessary.
See
Chapter 9 Changing the filter
12 Spare Parts
CAUTION! Risk of equipment damage
Use only Nederman original spare parts and ac-
cessories.
Contact your nearest authorized distributor or
Nederman for advice on technical service or
if you require help with spare parts. See also
www.nederman.com.
12.1 Ordering spare parts
When ordering spare parts always state the following:
• The part number and control number (see the
product identification plate).
Chapter 9 Changing the filter
cartridge.