mundoclima MUCNR-H9M Manual De Instalación Y De Usario página 56

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING for Using R32/R290 Refrigerant
When flammable refrigerant are employed, appliance shall be stored in a well -ventilated area
where the room size corresponds to the room area as specifiec for operation.
For R32 frigerant models:
Appliance shall be installed, operated and stored in a room with a floor area larger than
Appliance shall not be installed in an unvertilated space, if that space is smaller than
(Please see the following form)
Model
(Btu/h)
”18000
Reusable mechanical connectors and flared joints are not allowed indoors.
(EN Standard Requirements).
Mechanical connectors used indoors shall have a rate of not more than 3g/year at 25%
of the maximum allowable pressure. When mechanical connectors are reused indoors,
sealing parts shall be renewed. When flared joints are reused indoors, the flare part
shall be re-fabricated. (UL Standard Requirements)
When mechanical connectors are reused indoors, sealing parts shall be renewed. When
flared joints are reused indoors, the flare part shall be re-fabricated.
(IEC Standard Requirements)
.
Minimum room
area (m²)
18
56
.
X m²
X m²

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido