When cleaning is finished and recovery tank emptied:
1) Remove the power plug from the outlet
2) Disconnect the solution hose on the back of the machine.
2) Flush recovery tank with clean water to remove any remaining debris and then empty into toilet by
lifting up on the dump valve.
3) When the recovery tank is clean and emptied store the machine leaving the recovery tank open.
4) Coil power cord neatly after each use and store on machine with solution inlet hose Fig. 3.
5) Coil vacuum hose assembly and place in mesh storage bag. Hang on machine for storage and/or
transportation. Fig. 4.
Fig. 3
1) Remove any lint from the ball float screen (Fig. 5) in the recovery tank (it can be
removed if necessary) and any debris from the solution tank inlet filter (Fig. 6). A
damaged filter should be replaced, otherwise blockages and/or damage to the pump head
and spray jet can occur.
2) Check the spray jet on the wand for blockage and a uniform spray pattern. Remove jet
and blow through to clean. Do not use a pin or other sharp objects as this may cause dam-
age to the jet.
3) Check and remove any debris or lint build-up from the wand vacuum inlet.
4) Always wash out the tank with clean water after use.
5) Wipe down the machine with a damp cloth. Do not hose off or power spray machine.
6) Inspect solution hose and vacuum hose for cracks or damage. Do not use hose if
damaged.
7) Inspect electrical cord end on the machine for damage.
CAUTION: THIS UNIT MUST BE PROTECTED FROM FREEZING. Damage from
freezing could cause machine to malfunction.
Problem
Vacuum motor runs but poor suction Remove debris from vac shoe
No power, nothing works
Poor water spray
Vacuum motor will not run

Troubleshooting Table

Solution
Recovery tank too full - drain tank
Remove debris from suction hose
Plug in cord
Check for loose wiring
Call Service
Spray jets clogged - remove and clean spray jets
Check pump – remove spray jets and check water flow
Call Service
Activate vacuum switch
Check for loose wiring
Call Service
8
Fig. 4
Fig. 5
Fig. 6