IO Link Data Dictionary
21.10.01.00125
Diagnosis
Device Status
32
0x0020
0
Error Count
36
0x0024
0
IO Link Device Status
37
0x0025
0
Detailed Device Status
Active Errors
130
0x0082
0
138
0x008A
1
Extended Device Status Type
138
0x008A
2
Extended Device Status ID
139
0x008B
0
NFC Status
Condition Monitoring [CM]
146
0x0092
0
Condition monitoring
Energy Monitoring [EM]
Air consumption per cycle in percent
155
0x009B
0
156
0x009C
0
Air consumption per cycle
157
0x009D
0
Energy consumption per cycle
Predictive Maintenance [PM]
Quality
162
0x00A2
0
163
0x00A3
0
Performance
Coding of Extended Device Status (ISDU 138) and IO Link Events
Extended Device Status ID
Extended Device Status Type
(= IO Link Event Code)
dec
hex
hex
0
0x0000
0x10
Everything OK
6161
Defect/fault, high
0x1811
0x82
35872
0x8C20
0x81
Defect/fault, lower
2457
0x0999
0x81
Defect/fault, lower
20736
0x5100
0x42
Critical condiction, high
20752
0x5110
0x42
Critical condiction, high
6146
0x1802
0x42
Critical condiction, high
6156
0x180C
0x22
Warning, high
6151
0x1807
0x22
Warning, high
6152
0x1808
0x21
Warning, low
6153
0x1809
0x21
Warning, low
6154
0x180A
0x22
Warning, high
6155
0x180B
0x21
Warning, low
35841
0x8C01
0x21
Warning, low
6144
0x1800
(IOL event only)
6145
0x1801
0x22
Warning, high
6167
0x1817
(IOL event only)
6168
(IOL event only)
0x1818
30480
0x7710
0x41
Critical condiction, low
J. Schmalz GmbH
2 bytes
1 byte
96 bytes
2 bytes
1 byte
2 bytes
1 byte
2 bytes
1 byte
2 bytes
2 bytes
1 byte
1 byte
IO Link
Display Code
Event Type
Meaning
(no IOL event)
Error
E01
Error
FFF
(no IOL event)
E08
Error
E07
Warning
E17
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Notification
Notification
E03
Notification
Notification
Error
E12
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
Event name
Everything OK
Data Corruption
Measurement range overrun
IO Link communication interruption
General power supply fault
Primary supply voltage over run
Supply pressure fault
Primary supply voltage out of optimal range
CM: Valve protection active
CM: evacuation time above limit
CM: leakage rate above limit
CM: SP1 not reached
CM: free flow vacuum too high
Simulation active
Vacuum calibration OK
Vacuum calibration failed
Autoset completed successfully
Handling Cycle Completed
short circuit at OUT2
3 of 3
J. Schmalz GmbH
Johannes Schmalz Str. 1, D 72293 Glatten
Tel.: +49(0)7443/2403 0
Fax: +49(0)7443/2403 259
info@schmalz.de
Number of errors since last power up
0 = Device is operating properly
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
Information about currently pending events
Fixed length array format according to IO Link specification V1.1
Bit 00: Internal error: data corruption (E01)
Bit 01: reserved
Bit 02: Primary voltage too low (E07)
Bit 03: Primary voltage too high (E17)
Bit 04 07: reserved
Bit 08: short circuit at OUT2 (E12)
Bit 09 10: reserved
Bit 11: Measurement range overrun (FFF)
Bit 12 14: reserved
Bit 15: IO Link communication interruption (E08)
Type code of active device status (see below)
ID code of active device status (see below, corresponds to IO Link events)
Result of recent NFC activity:
0x00: Data valid, write finished successfully
0x23: Write failed: Write access locked
0x30: Write failed: parameter(s) out of range
0x31: Write failed: parameter value too high
0x32: Write failed: parameter value too low
0x41: Write failed: parameter set inconsistent
0xA1: Write failed :invalid authorisation
0xA2: NFC not available
0xA3: Write failed: invalid data structure
0xA5: Write pending
0xA6: NFC internal error
Bit 0: Valve protection active
Bit 1: Evacuation time t1 above limit [t 1]
Bit 2: Leakage rate above limit [ L ]
Bit 3: SP1 not reached in suction cycle
Bit 4: Free flow vacuum > rP2 but < SP1
Bit 5: Primary voltage US outside of optimal range
Bit 6: reserved
Bit 7: reserved
Bit 8: Input pressure outside of operating range
Bit 9 15: reserved
Air consumption of last suction cycle (unit: 1 %)
Air consumption of last suction cycle (unit: 0.1 Nl)
Energy consumption of last suction cycle (unit: 1 Ws)
Quality of last suction cycle (unit: 1 %)
Last measured performance level (unit: 1 %)
Remark
Device is working optimally
Internal error, user data corrupted
Measured vacuum value too high, sensor fault
IO Link communication is interrupted (readable via NFC)
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Input pressure too high or too low
Condition Monitoring: primary supply voltage US outside of operating range
Condition Monitoring: valve has switched too fast, continuous
suction activated
Condition Monitoring: evacuation time t1 is above limit [t 1]
Condition Monitoring: leakage rate is above limit [ L ]
Condition Monitoring: vacuum level SP1 was never reached during
suction cycle
Condition Monitoring: free flow vacuum above SP2
Manual mode is active
Calibration offset 0 set successfully
Sensor value too high or too low, offset not changed
Permissible leakage and permissible evacuation time have been set
automatically for the active profile
Handling of the part is complete (neutral state of vacuum system reached
or new suction phase begun)
output is connect with counterpotential
SCPMi
14.06.2019
SCPMi Data Dictionary