3 Set-up and installation
3.7.10
Connecting the room thermostat
INFORMATION
A
separate
manual
installation and operation is included with this component.
3‒39 Connection with wired room thermostat (RT = Daikin
EKRTW)
3‒40 Connection with radio-controlled room thermostat (RT-E =
Daikin EKRTR)
3.7.11
Connection of optional RoCon system
components
The optional RoCon devices must be connected to the indoor unit
via a 4-wire CAN bus cable (connection J13).
For this, we recommend shielded lines with the following
characteristics:
▪ Standardisation according to ISO 11898, UL/CSA type CMX
(UL 444)
▪ PVC
outer
sheath
with
IEC 60332-1-2
▪ Up to 40 m, minimum cross-section 0.75 mm
cross-section necessary with increasing length.
Commercially available junction boxes can be used to connect CAN
bus lines of several RoCon devices.
Installation and operating manual
26
containing
instructions
about
flame
retardancy
according
2
. Larger conductor
Ensure that mains, sensor and data bus lines are routed separately.
Use only cable ducts with separators or separate cable ducts spaced
at least 2 cm apart. Line crossings are permissible.
A maximum of 16 devices with a total line length of up to 800 m can
be connected in the entire RoCon system.
EHS157034 room controller
A separate EHS157034 room controller can be connected for each
heating circuit to enable remote adjustment of operating modes and
room target temperatures from another room.
INFORMATION
Separate installation instructions are included with this
component. See the enclosed control system manual for
instructions on setting and operation.
EHS157068 mixer module
The EHS157068 mixer module can be connected to the indoor unit
(J13 PCB connector) and is controlled by the electronic controller.
INFORMATION
Separate installation instructions are included with this
component. See the enclosed control system manual for
instructions on setting and operation.
EHS157056 Internet gateway
The controller can be connected to the internet with the optional
EHS157056 gateway. This enables remote control of the indoor unit
by mobile phones (by app).
INFORMATION
Separate installation instructions are included with this
component. See the enclosed control system manual for
instructions on setting and operation.
3.7.12
Connecting the HP convector
INFORMATION
Only the EKRTCTRL1 and EKWHCTRL(0/1) convector
controllers can be connected to the indoor unit.
INFORMATION
A
separate
installation and operation is included with this component.
INFORMATION
When changing the operating mode (Heating/Cooling) on a
convector, all other convectors must either also be
changed or deactivated.
to
manual
containing
instructions
Daikin Altherma EHS(X/H)(B)-D
Daikin Altherma 3 R ECH₂O
008.1451099_00 – 07/2020
about