knowledge, unless they are supervised
by a person responsible for their safety
or have been instructed on how to use
the machine. Children should always be
supervised to ensure that they do not play
with the machine.
- If used to extract dusts with LTL values or
large quantities of beech or oak sawdust,
only one dust source (electric or air tool)
may be connected.
- The appliance may be operated only in an
adequately ventilated space (in compliance
with national industrial safety provisions).
- Do not suck in any sparks or hot chip-
pings.
- With the exception of wood dust, do not
suck in any fl ammable or explosive dusts
such as magnesium, aluminium etc. - Risk
of explosion!
- Do not use to extract fl ammable or explo-
sive liquids (e.g. petrol, thinners) - Risk
of explosion!
- Do not use to extract aggressive liquids/
dry materials (e.g. acids, alkalis, sol-
vents).
- Remove plug from mains socket when not
in use and before maintenance work.
- Do not pull plug out of mains socket by
its cable.
- Protect the cable against heat, oil and
sharp edges.
- Check the plugs and cables regularly and
have them replaced by an expert if dam-
aged.
- Do not leave devices out in the rain.
- Do not lift or carry the devices by their
handles using a crane hook or lifting gear.
- The device may only be used by persons
who have been trained in its use and who
are authorised to do so.
- If noxious dusts have been extracted,
the vacuum cleaner and all accessories
must be completely cleaned (inside and
outside) by suction and wiping, before re-
moval from the contaminated area. Parts
that cannot be completely cleaned are to
be packed for transport in a plastic bag
with an airtight seal. The suction opening
(1.14) must be sealed with the blanking
plug (1.13) for transport purposes.
- For safety reasons, only operate the ma-
chine using a totally earthed socket.
3
Appliance preparation and initial
operation
The accessories are delivered horizontal in
the container (2.10), and must be removed
prior to initial operation.
3.1
Power supply
The line voltage and frequency must
correspond with the data on the rat-
ings plate!
Make sure that the vacuum cleaner is
switched off when you plug the power cable in.
The antistatic system (AS)
Friction in the suction hose causes electro-
static charges which can result in unpleas-
ant electric shocks for the operator. In order
to conduct these static charges to earth,
the extraction units are provided with an
antistatic system as a standard feature.
However, antistatic hoses and accessories
have to be used in this case. The antistatic
function will only work if the plug is plugged
into a totally earthed socket.
3.2
On/off switch (1.3)
In position 0 the vacuum cleaner is switched
off and the appliance plug socket (1.7) is
dead. Before switching on, the rotary knob
(1.2) must be adjusted to the diameter of
the connected suction hose.
Two modes of operation are possible:
a)
Switch position „MAN"
The appliance plug socket is dead.
The cleaner motor starts immediately.
b)
Switch position „Auto"
The appliance plug socket is live.
Before turning the switch to the
„Auto" position, ensure that the
tool connected to the appliance plug
socket is switched off.
The cleaner motor starts only when the tool
connected to the appliance plug socket is
switched on.
3.3
Suction force regulator (1.4)
The suction force regulator can be used to
vary the suction capacity. This permits a
precise adaptation to different substances
to be picked up.