Intended use of the product

This product serves exclusively accelerate the curing of
putty, filler, base and clear coats. The product must not
be used for other purposes than the described curing
processes.
The maximum ambient temperature during operation
should not exceed 40°C.
Do not use the product in spray booths or within a dis-
tance of 5 m from other solvent based spraying activities
in order to avoid explosion risks.
2.

Product description

The easily manoeuvrable IRT-UVA PrepCure is equipped
with one cassette. The cassette is equipped with one
high efficiency 1000 W UVA-lamps which make the
curing extremely fast.
The time can be set to 0-30 min.
UV curing
The ultraviolet light spectrum generated by a UV lamp
interacts with special coating chemistries to produce a
high-quality, durable curing. In many applications, UV
curing can achieve the curing faster and therefore at a
lower total cost than many other coating processes.
UV-coat contains less solvent than conventional paint
and from that perspective has less negative environ-
mental impact.
Most importantly to achieve a good and fast curing result
there must be enough UV-A intensity. IRT UVA PrepCure
has an outstanding intensity to achieve the best curing
result.
Unique benefits of the UV cure coating
Reduced amount of solvent
Fast curing time
Low-temperature processing
Scratch resistant and chemical resistant
3.

Technical data

Curing area
1,0 m
Curing area at 55 cm distance for a UVA 1 is 1,0x1,0 m
(H x W) with an UV-A intensity of 25 W/m².
Consult your paint supplier to find out what intensity
your paint material needs.
714598 rev 5
IRT-UVA-1 PrepCure 3 Digital is in excess of the Exempt
Group and viewer-related risk is depending upon the
use of the product.
IRT-UVA-1 PrepCure 3 Digital
Voltage
Frequency
Current
H.I.D. UV bulb light
Lamp wattage
Noise level
Risk Group EN62471
3
2
1
Exempt
Hazard Distances (HD)*
HD
Ex
HD
RG1
HD
RG2
HD
RG3
Exposure Hazard Value EHV at above hazard distances
EVH
Ex
EVH
RG1
EVH
RG2
*Total distance from light source. For reflected light,
summarize distance to reflecting surface and distance
between lamp and reflecting surface.
4.

Instruction to the owner

The owner of the mobile dryer must produce clear oper-
ating instructions, adapted to local site conditions, and
make these available to all users.
Mobile dryer users must adhere to these operating in-
structions.
This appliance is not intended for use by persons (includ-
ing children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concern-
ing use of the appliance by a person responsible for
their safety.
Dispose of spent items at the nearest environmental
protection facility for recycling.
The UV- radiation emission is:
according to EN12198 = Category 2
according to EN62471 = Risk group 3
Appropriate measures shall be taken.
GB
230 V 1 ~/PE
50-60 Hz
5 A
High pressure metal halide
lamp
1000 W
< 70 dB (A)
0-0,5 m distance
0-5-1,5 m distance
1,5-2,0 m distance
> 2,0 m distance
>2,0 m (Exempt Risk Group)
1,5-2,0 m (Risk Group 1)
0,5-1,5 m (Risk Group 2)
< 0,5 m (Risk Group 3)
<0,95
<0,55
<1,0
3