14. TECHNICAL CHARACTERISTICS OF THE EQUIPMENTS POOLWATCH BASIC ECO pH / INORGANIC CHLORINE
-
Measure range pH: 0 to 14 (resolution: 0.01 unit)
-
pH Set Point range: 0 to 14
Cl Measure range: 0 to 10 (resolution: 0,01 unit)
-
-
Cl Set Point range: 0 to 10 ppm
-
Delay: 10 seconds
Calibration to pH 7 and pH 4
-
-
Power consumption of equipment: 5W
-
Feed tension: 220 V Monophasic + Earth, 50 Hz
-
Commutation hysteresis per time: +/- 10 seconds
TECHNICAL SPECIFICATIONS POOLWATCH BASIC ECO pH / INORGANIC CHLORINE
-
Controller and/or Inorganic Chlorine regulator.
-
Visualisation through LCD display backlightened alphanumeric (16 characters)
24 bits dynamotor ADC with balanced lining up of temperature digital filtering reading to have a high immunity to jamming.
-
16 bits microprocessor.
-
-
2 regulation outputs ON/OFF (relay) (free power connectors)
-
Optional Temperature output
Optional output 4-20 mA
-
-
Optional communication output.
-
Multilanguage programme.
Warning of faulty electrode in calibration.
-
Optoisolated inputs with probe protection and isolation between sonde input (<10 KV)
-
It is advisable to make a review once a year by a specialised technician.