Interface - TBH LN-Serie Instalación Y Manual De Funcionamiento Y Mantenimiento

Ocultar thumbs Ver también para LN-Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Conditions of ambiance, storage
and transportation
Operation temperature
Relative humidity max.
Usage
Altitude above MSL max.
8.1

Interface

SUB-D (25 pin)
Caution ! Max. contact load 40V/1A for all relay contacts!
Subject to technical changes. No liability for damage caused by incorrect interpretation or incorrect wiring. For further
information please contact your respective partners.
Pin
Signal Name
01
-
02
-
03
-
Filter saturated
04
inverted
05
Filter saturated
06
Filter saturated
07
Start / Stop
08
Start / Stop
09
Jumper RUN
10
Jumper RUN
11
speed low
speed low /
12
temperature
13
temperature
external speed
14
regulation
-
external speed
15
regulation
+
°C
%
m
Filter condition OK: Relay contact closes between pin 04 and pin 05.
Filter saturation 75%: Relay contact opens between pin 04 and pin
05 – only LN/GL/CR-Series
Common relay contact for filter saturated inverted (pin 04) and for
filter saturated (pin 06) – only LN/GL/CR-Series
Relay contact opens between pin 05 and pin 06
Filter saturation 75%: Relay contact closes between pin 05 and pin
06 – only LN/GL/CR-Series
Control signal must by applied → not potential free!
Start/Stop via interface active if system in stand-by mode –
configuration not relevant (e.g. Pin 07 + / Pin 08 - )
On/off condition of the system: Run operation (PIN 09 a. PIN 10
open)
Stand-by operation (PIN 09 and PIN 10 connected)
speed O.K.: relay contact closes between pin 11 and pin 12
speed too low: relay contact opens between pin 11 and pin 12
Common relay contact for speed low (Pin 11)
Temp. O.K.: Relay contact closes between pin 12 and pin 13
Temp. too high: Relay contact opens between pin 12 and pin 13
By applying 3-10V DV (pin 14 and pin 15), speed can be controlled
external
For this, it is necessary to set the speed regulation at the device to
lowest value
8 Technical Data
5 to 40
80 without bedewing
Damaging effects of conditional bedewing can be prevented by a
special by-pass air guidance
In interior rooms only. Dust load of ambiance air must not bee too
high.
2000
Description
and for temperature (Pin 13)
74-198
Control voltage/
configuration
Pin 04
Pin 05
Pin 06
Wechsler - Relaiskontakt
12V-30V AC/DC
(Bipolar optocoupler)
Pin 11
Pin 12
Pin 13
Öffner - Relaiskontakt
3V-10V DC
(Bipolarer optocoupler)
min. 10mA