Output Specifications; Specification - TTI CPX200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

OUTPUT SPECIFICATIONS

Voltage Range:
Current Range:
Power Range:
Output Voltage Setting:
Output Current Setting:
Operating Mode:
Output Switch:
Output Terminals:
Sensing:
Output Protection:
OVP Range:
Line Regulation:
Load Regulation:
Ripple & Noise
(20MHz bandwidth):
Transient Load Response:
Temperature Coefficient:
Status Indication:
2
0V to 35V
0A to 10A
Up to 175W
By coarse and fine controls.
By single logarithmic control.
Constant voltage or constant current with automatic cross-over
provided that the power demanded stays within the power
envelope, see graph. Outside of this envelope the output becomes
unregulated.
Electronic. Preset voltage and current displayed when off.
Universal 4mm safety binding posts on 19mm (0·75") pitch.
Switchable between local and remote. Spring-loaded push terminals for
remote connection.
Forward protection by Over-Voltage Protection (OVP) trip; maximum
voltage that should be applied to the terminals is 50V.
Reverse protection by diode clamp for reverse currents up to 3A.
10% to 110% of maximum output voltage set by front panel screwdriver
adjustment.
<0.01% of maximum output for a 10% line change.
<0.05% of maximum output for a 90% load change, using remote sense.
5mVrms max; typically <2mVrms, <20mV pk-pk, both outputs fully
loaded (7A @ 25V), constant voltage mode.
<2ms to within 100mV of set level for a 5% to 95% load change.
Typically <100ppm/°C
Output on lamp.
Constant voltage mode lamp.
Constant current mode lamp.
Unregulated (power limit) lamp
Trip message on display.