CAUTION: Voltage Hazard.
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
Wire entire panel before applying transformer power.
Follow these steps for wiring all systems. However, wiring will vary depending on equipment. For conventional sys-
tems, refer to this page. For heat pump systems, see pages 5 and 6. For dual fuel systems, see pages 7 and 8.
Wiring must comply with applicable codes, ordinances, and regulations. Use the following wiring diagrams to wire
the zone panel to the thermostats and dampers.
Install thermostats using instructions provided with thermostats.
3
Connect thermostat to zone panel. To connect wire to the panel, strip
approximately 1/4 in. of insulation and push wire into terminal. To
release wire, press the button on top of the terminal.
The HZ432 offers many innovations for wire management and organization: wires can be run
behind the panel, through wire channels on its sides, and must be attached to a wiring anchor
with a cable tie.
M24743
Fig. 5
Install dampers using instructions provided with dampers.
4
Connect dampers to zone panel.
NOTE: Multiple dampers can be wired in parallel.
ARD OR ZD DAMPER SPRING-OPEN POWER-CLOSED
REGISTRE ARD OU ZD OUVERTURE PAR RESSORT FERMETURE MOTORISÉE
HUMIDIFICADOR ARD O ZD CON APERTURA ACCIONADA POR RESORTE Y CIERRE
ARD OR ZD DAMPER SPRING-OPEN POWER-CLOSED
REGISTRE ARD OU ZD OUVERTURE PAR RESSORT FERMETURE MOTORISÉE
HUMIDIFICADOR ARD O ZD CON APERTURA ACCIONADA POR RESORTE Y CIERRE
M1 COMMON • COMMUN • COMÚN
M4 OPEN • OUVERT • ABIERTO
M1
M4
M6 CLOSED • FERMÉ • CERRADO
M6
R
RRD OR MARD DAMPER POWER-OPEN POWER-CLOSED
REGISTRE RRD OU MARD OUVERTURE
MOTORISÉE FERMETURE MOTORISÉE
HUMIDIFICADOR RRD O MARD CON
APERTURA ACCIONADA POR ENERGÍA Y CIERRE
Fig. 6
MFS24922
HZ432 TrueZONE
WiriNg
M1
M4
M6
R
Rc
C
R
W1/E
C
W2
W
W3
W2
Y
Y1
Y2
Y2
G
G
O/B
L
Fig. 4
69-2070EFS—0
M24808