6.3
PLUMBING SYSTEM
Connection to the plumbing system and the
plumbing system must be in compliance with
current national laws and standards, and realized
by quali ed personnel.
1. Make the water connections to the boiler body
as described on the datasheet in the Product
Booklet.
2. Make sure that all the control and safety
devices including those supplied with the
stove are installed correctly (safety and heat
exhaust valves).
You MUST NOT insert devices that completely
close the heating system (zone valves). For safety
reasons, the pump must ALWAYS run while the
stove is on, dispersing the heat produced. If there
is too much ambient heat, reduce the volume of the
ame, if necessary put it out.
IN order to service the plumbing connections for
easily accessing it:
• Open the door (1).
• Unscrew the front xing screws and remove the
front panel (2)
• Unclip the control panel connection cable (3)
• Unscrew the front and rear xing screws of the
Top. (4)
• Pull the top upwards. (5)
• Unscrew the backrest screws (6)
• Remove the backrest (7)
7
INSTALLATION
1
2
4
6
5
3
13