-The cooling pad surfaces must be
periodically inspected and sanitised
depending on the use.
-For sanitation operations, biocidal
products that comply with European
regulation no. 582/2012 must be used.
►►2. UNPACKING
►2.1. Remove all packaging material
used to pack and deliver the cooler and
dispose of it in compliance with current
standards.
►2.2. Remove all items from the packag-
ing.
►2.3. Check for any damage incurred
during transport. If the cooler appears
damaged, immediately inform the dealer
from whom it was purchased.
►►3. ASSEMBLY
The cooler is equipped with an air duct-
ing kit and wheels to facilitate handling.
Depending on the model, all the compo-
nents can be found already installed or to
be installed. Components equipped with
relative nuts and bolts are found inside the
packaging (Fig. 2).
►►4. OPERATION
WARNING: Carefully read the "SAFETY
INFORMATION" before switching on the
cooler.
WARNING: Only use clean water to pre-
vent failures or other anomalies.
WARNING: Verify if your electronic sys-
tem is earthed correctly. Connection to
the mains must be made in compliance
with the National Standards in force.
Only power the cooler with the voltage
and frequency as specified on the name-
plate.
►►4.1. SWITCH-ON:
►4.1.1. Connect the cooler to the water
mains using the threaded fitting (Fig. 3).
►4.1.2. Refilling the water tank. When the
tank reaches the maximum level, a float
automatically stops the flow of water.
CAUTION: You can operate the cooler
while connected to and continuously fed
by the water supply.
►4.1.3. Check that there are no leaks dur-
ing refuelling.
►4.1.4. Connect the supply plug to the
power mains (Fig. 4).
►4.1.5. Press ON/OFF / POWER to turn
on the cooler (Fig. 6).
►►4.2.1. FUNCTIONS OF THE
CONTROL PANEL AND REMOTE
CONTROL (Fig. 5):
►ON/OFF: Used to turn the cooler on or
off.
►AUTO: Activates the automatic cooling
and cleaning function.
►COOL: Activates or disables the cooling
mode (ventilation does not start imme-
diately).
►VENT: Activates or disables the ventila-
tion mode.
►CLEAN: Mode not available.
►REVERSE: Reverses the direction of ro-
tation of the fan, to introduce or remove
air from the room.
►SWING: Mode not available.
NOTE: Enables or disables the auto-
matic swing of the baffles to direct the air
flow by pulling the rope on the air outlet
opening.►▲ \ ▼: Adjust the ventilation
speed and the display clock.
en