After installing the blade, always adjust the blade clear-
ance. (Refer to "Adjustment for blade clearance".)
To install the shear blades, perform the procedures
above in reverse. When installing the shear blades, pay
attention to the following points:
•
Apply machine oil or grease on to the blade tight-
ening bolt and between the blades.
•
If you can not place the plate fixing bolt properly,
first, remove the O-ring and the plate fixing bolt
from the lock plate. And then overturn the lock
plate, and return the O-ring and the plate fixing
bolt.
•
When installing the trigger guard, align the tongue
of the trigger guard with the groove of the housing.
►Fig.36
•
Make sure all the bolts are securely tightened.
•
After installing the blade, always adjust blade
clearance. (Refer to "Adjustment for blade
clearance".)
•
After installing the blade, always adjust cutting
depth. (Refer to "Cutting depth adjustment".)
Trouble shooting
Before making a request for repairs, check for trouble
by yourself. If any abnormality is found, control your
tool according to the description of this manual. If the
remedy mentioned below cannot solve the problem, ask
your local authorized service center for repair. Never
tamper or dismount any part contrary to the description.
State of
Probable cause
abnormality
(malfunction)
The shear blade
The battery is
does not move
low.
even after pull-
I/O switch is "Off"
ing the trigger
position.
switch.
The shears are
locked.
Connection cord
is loose.
Switch trigger
defect.
The shear
The branch is too
blades are stuck
thick.
on the branch.
The switch
Shear blades are
trigger is locked
opened forcibly.
and can not be
pulled.
The cut is not
The shear blades
smooth.
are dull.
The shear blades
are worn out.
Remedy
Charge the battery.
Press the I/O switch to
"I" position.
Unlock the shears by
performing the steps in
"Switch action".
Check the connecting
points of the switch box
and shears of connec-
tion cord.
Stop using the tool
immediately, and ask
your local authorized
service center for
repair.
Release the switch
trigger. Press the I/O
switch to "O" position.
Then pull the blades
straight out slowly from
the branch.
Switch off and on with
the I/O switch. (The
upper shear blade
closes slightly when
switching on.)
Sharpen the shear
blades, or adjust blade
clearance.
Replace the shear
blades.
To maintain product SAFETY and RELIABILITY,
repairs, any other maintenance or adjustment should
be performed by Dolmar Authorized or Factory Service
Centers, always using Dolmar replacement parts.
OPTIONAL
ACCESSORIES
CAUTION:
These accessories or attachments
are recommended for use with your Dolmar tool
specified in this manual. The use of any other
accessories or attachments might present a risk of
injury to persons. Only use accessory or attachment
for its stated purpose.
If you need any assistance for more details regarding
these accessories, ask your local Dolmar Service
Center.
•
Upper shear blade
•
Lower shear blade
•
Diamond file
•
Arm band
•
Holster
•
Cord holder
•
Makita / Dolmar genuine battery and charger
NOTE: Some items in the list may be included in the
tool package as standard accessories. They may
differ from country to country.
ENGLISH