INSTALLATION INSTRUCTIONS
NOTICE
The installation should be performed only by an authorized gasfitter

1.1 General instructions

*
The gas fireplace must be installed, connected and inspected as a balanced flue fire by a qualified fitter,
according to national, regional, and local standards and regulations.
*
The flue system and the terminals in the outer wall or roof face must also meet the requirements
outlined in the applicable standards and regulations.
*
The temperature of the walls and shelves near the side and back of the unit may not be more
than 80°C higher than the temperature of the environment.
*
The unit has been approved in combination with the THC CC Ø100 mm - Ø150 mm and
Ø130 mm - Ø200 mm , in accordance with European CE standards for gas fires, and may therefore
only be applied with this system.
*
The product needs to be serviced and inspected by the fitter for local gas distribution as indicated on
the identification plate.
*
The instructions are only applicable if the relevant country code is stated on the unit. If this is not the
case, the gas technical information for the relevant country needs to be consulted and modifications
discussed with the manufacturer.
*
There will be air in the gas pipes when the unit is first used. The gas pipes therefore need to be purged first.
*
Ignite the fire according to operating instructions and check whether the burner flame is uniform.
After the unit has been used for the first time, you should remove any deposits resulting from
Running/burning in the paint, using a glass cleaner for heaters.
Distance to flammable materials:
*
With respect to the front, side and top of the unit, a distance of 1200 mm needs to be kept between
the unit and: curtains, floor covering, upholstery and fabrics, and/or other flammable material unless
stated other wise in these instructions.
Distance to non-flammable materials:
*
The unit needs to be placed a minimum distance of 25 mm from the wall unless stated otherwise in
these instructions.
WARNING
Gas fires become hot when they are in operation. After installing the appliance the glass surface
is considered active zone. The glass surface can become very hot.!
Attention! Accordingly, care should be taken, for example children and needy in the vicinity of
burning fires are banned. Gas fires must not be on or against flammable materials are placed
(curtains etc.).
Never install the unit against or within a flammable wall!.
NOTICE
Construction material for fireplaces and mantles etc. or built-in situation, must be made of
non-combustible material. This also applies to floors and ceilings. Never use flammable
materials near the unit in compliance with the above requirements.
If in doubt, consult your dealer