13. After a few seconds from arrival at respective stop, both motors will automatically stop. The "TEMPI"
led lights fixed on, operation time learning has finished. At this point press repeatedly the "SEL" key to
select any other programming function or to exit the programming (all leds are turned off).
Once the control board programming is ended, press repeatedly the "SEL" key until all leds are turned off.
At this point the control board is ready to receive commands.
9 MAINTENANCE
WARNING Any installation, maintenance or repair operation on the whole system must be carried
out exclusively by qualified personnel. All these operations must be performed only after disconnecting
the power supply, and operating in strict compliance with the electrical standards and regulations in
force in the nation of installation.
10 PRODUCT DISPOSAL
WARNING Disposal of packaging materials (such as plastic, card board, etc.) must be done ac-
cording to regulations in force locally. Do not leave plastic bags and polystyrene within the reach of
children
Demolition of this product does not cause particular dangers. Whenever the regulations in force in the
country of installation demand it, it is always advisable and necessary to dispose suitably and separately
of each material that make up the product: plastic, ferrous materials, batteries and electric parts.
11 COMPLETE CLOSING ASSEMBLY
Remember that everyone who sells and/ or automates doors/gates becomes the manufacturer of the
automated door/gate machine, and must therefore prepare and preserve a technical folder containing
the following documents (see Machinery Directives Enclosure V).
• Assembly drawing of the automated door/gate.
• Electrical connection and control circuit diagram.
• Risk analysis including: a list of the essential safety requirements provided in machine Directive
Enclosure I; a list of the risks posed by the door/gate and a description of the implemented solutions
The installer must also:
• Keep these operating instructions and the instructions for all other components in a safe place.
• Prepare the operating instructions and general safety warnings (by filling up these operating instruc-
tions) and hand a copy to the end user.
• Fill in the maintenance handbook and hand a copy to the end user.
• Draw up the EC declaration of conformity and hand a copy to the end user.
• Fill in the complete EC label or plate and apply it to the automated door/gate.
N.B. The technical folder must be kept for inspection by the competent national authorities for at least
ten years starting from the date of manufacturing of the door/gate operator.
WARNING DEA System reminds all users that the selection, positioning and installation of all ma-
terials and devices which make up the complete automation system, must comply with the European
Directives 98/37/CE (Machinery Directive), 89/336/CE and subsequent amendments (electromagnetic
compatibility), 73/23/CE and subsequent amendments (low voltage electrical equipment). In order to
ensure a suitable level of safety, besides complying with local regulations, it is advisable to comply also
with the above mentioned Directives in all extra European countries.
Operating instructions and warnings
A5
A5
11
R
2 0 2 E