TECHNICAL DATA
Capacity
Material
Thickness
Finishing
Degree of protection
Anchor
Wiring
Weight
Dimensions
Foundation recommended
Fixation
* The totem is considered a support for the wallboxes and the IP and IK degree is
provided by the rubber wallbox selected.
INSTALLATION
To carry out the installation, follow the instructions defined in the REBT
and especially the ITC-BT-52. More information about the requirements
of the electrical parameters necessary for a correct charging and the par-
ticular installation aspects of each wallbox are available on their respecti-
ve installation instructions.
If a bollard impact protection is installed, maintain a minimum distance
of 500mm so that there is enough space to open the totem door when
performing maintenance.
There are two ways to install the totem:
- CASE A: Making a foundation by fi lling a hole in the fl oor
with concrete.
- CASE B: By making 4 holes with a drill and fi lling them
with cement-glue.
Regardless of the installation method chosen, the basic dimensions of anchoring
and the path of the electrical wiring must be taken into account:
180mm
50mm
100mm
1 Rubber Wallbox
Aluminium
2,5mm
Polyesther paint Black (BKTECH)
and aluminium (GYTECH)
IP3X / IK8 (IP54 / IK10)*
4 points on the fl oor
Internal, with installer
access cover
10 kg
1510x270x226mm
400x400x300mm
Threaded Rods M12
Threaded rod
50mm
Hole for the
wiring
For a proper installation according to CASE A, the following steps must be
followed:
A.1. Prepare the anchor kit:
A.2. Make the totem foundation:
First pass the
electrical conduit
400mm
400mm
300mm
A.3. Insert the anchor kit in the hole:
Leveled
as possible
8