Function
Range
DC Voltage
200.0 mV
2000 mV
20.00 V
200.0 V
600 V
To Measure Resistance:
Resistance is measured in Ohms.
1. Turn the power off to the circuit or device that is to be mea-
sured and discharge all capacitors before measurement is
to be taken.
2. Plug test leads into the meter inputs as indicated in the
following diagram.
3. Select the proper range within the Ω function of the tester.
4. Measure resistance. If necessary, perform the required
multiplication to acquire the actual resistance.
4.1
Range Guide for Ohms (Ω):
200 = Meter indicates actual resistance
2K
= Multiply meter display reading by 1,000 to
acquire actual resistance.
20K = Multiply meter display reading by 1,000 to
acquire actual resistance.
200K = Multiply meter display reading by 1,000 to
acquire actual resistance.
2M
= Multiply meter display reading by
1,000,000 to acquire actual resistance
200M = Multiply meter display reading by
1,000,000 to acquire actual resistance.
5.
The meter displays total resistance through all possi-
ble paths between the probe-tips. These multiple
paths may result in measurements that do not corre-
spond to the ohm value indicated by the resistor
color code.
Page 5
Resolution
Accuracy
.1 mV
± (0.5% +1)
1 mV
± (0.5% +1)
.01 V
± (0.5% +1)
.1 V
± (0.5% +1)
1 V
± (0.5% +1)
Resistance (Ohms)
Meter Setup:
Red
Black
Function
Range
Resolution
Resistance
200.0Ω
2.000KΩ
20.00KΩ
200.0KΩ
2.000MΩ
20.00MΩ
Determining Resistor Values:
To determine the value of a resistor, use the color bands on the
resistor and the following table.
Circuit Connection:
Accuracy
.1Ω
± (1.0% + 4)
.001KΩ
± (1.0% + 4)
.01 KΩ
± (1.0% + 4)
.1KΩ
± (1.0% + 4)
.001MΩ
± (1.0% + 4)
.01 MΩ
± (2.0% + 4)