Diode Testing - Ideal Test Pro 360 Serie Manual De Instrucciones

Ocultar thumbs Ver también para Test Pro 360 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Read the forward voltage drop on the digital display:
5.1
A good silicon diode will result in a reading around
0.7 V.
5.2
A good germanium diode will result in a reading
around 0.3 V.
5.3
A short is indicated by a continuous beep and a
reading of .000 V.
5.4
An open is indicated by a 1. V reading.
6. Reverse the test probe connections to the diode and per-
form a reverse-leakage test of the diode.
6.1
A reading of 1. V indicates reverse blocking and a
good diode.
6.2
A reading of .000 V and a continuous beep indicates
high reverse leakage current or a short.

DIODE TESTING

Meter Setup:
Red
Black
Function
Range
Resolution
Diode Test
3 VDC
To Measure AC Current:
Current is measured in amps.
Do not attempt to measure current in circuits capable of deliv-
ering greater than 600V. If the current is unknown, begin at the
highest range, selecting the next lowest until a reading is dis-
played.
Page 9
Circuit Connection:
Accuracy
1 mV
± (1.5% + 1)
To Measure AC Current (cont.):
1. Connect the test leads into the meter inputs as indicated in
the following diagram.
2. Select the proper range to be used within the AAC area.
3. Turn the power off.
4. Connect the meter in series with the load or circuit.
5. Turn power on.
6. Measure AC Current.
Meter Setup:
Current <200mA AC
Red
Black
Circuit Connection:
Function
Range
Resolution
AC Current
200.0µA
20.00 mA
200.0mA
20.00A
Current AMPS>200mA AC
10 Amps Max.
Red
Accuracy
.1µA
±(1.5% + 4)
.01 mA
±(1.5% + 4)
.1mA
±(1.5% + 4)
.01A
±(2.5%)
Page 10
Black

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Test pro 61-360

Tabla de contenido