Novoferm NovoSpeed Flex Manual Del Usuario página 9

Puerta de alta velocidad
Ocultar thumbs Ver también para NovoSpeed Flex:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8.5
"OPEN/CLOSE" mode
In the same operation mode as the 1 track
regulations using red/green traffic light
(optional traffic light operation (A800), but the
receiver remains connected to the driver.
Progress of the operation for external impulse
generators:
Impulse emitted in "CLOSED" position:
Drive starts and brings door to the "OPEN"
position.
Impulse emitter during the movement to
the "OPEN" position: Without influence,
the door continues to open.
Impulse emitted in "OPEN" position: Door
is closed.
Impulse emitted during the movement to
the "CLOSED" position: Door stops and
starts to open.
8.6
AR operation shortened by light curtain
This function operates as described above, but
the interruption of the light curtain circuit
breaks the set opening time and the warning
period starts. At the end of the warning period
the door closes automatically.
8.7
Door half open
Press the [½] button to control the door to the
½ open position (menu 32). This function is not
available in the dead-man button OPEN/dead-man
button CLOSE operation mode.
8.8
Lighting and/or warning light
The control has 2 relay outputs that switches the
lighting or the warning light (menus 45 and 46).
8.9
Key switch function (option)
The control has an input for a key switch. This
gives you the option to activate the following
functions (menu 50):
This user manual must be given to the customer and must be kept within easy reach during the entire period of use.
English user manual
1.
Impulse emitter "OPEN - STOP - CLOSE"
2.
The operation of the control is blocked
3.
All external operation elements are blocked
4.
The operation of the control and all the
external operation elements are blocked
5.
During a period of 10 seconds, the operation
of the control and all external operation
elements are enabled
6.
Switching the operating mode to Impulse
OPEN/Dead-man button CLOSE
7.
Only ½ open door
8.10
External command units/impulse emitters
The door can be opened and closed via external
command units/impulse emitters.
8.11
Wireless hand-held transmitter (option)
Key: 'Start' Emit first impulse: The drive
starts and moves the door to the set OPEN
or CLOSE end position.
Emit impulse during the movement: The
door stops.
Emit another impulse: The door continues
to move in the opposite direction.
AR operation:
Impulse: Door open.
Key for door half open:
Function as for the Start key, the door is, however,
only half opened to the preset position.
Key: Lighting function
The lighting function is related to a continuous light
that can be switched "on" and "off" independently
of the movement of the door.
Service message
8.12
When the control detects that a check is performed,
the service message is lighted. Contact your
specialist company in that case.
EN
7

Publicidad

Tabla de contenido
loading

Tabla de contenido