- drain the appliance, if necessary
- check its operation from time to time.
USER INSTRUCTIONS
CAUTION Observe all general warnings and safety standards listed at the begin-
ning of this text in full; all such instructions are obligatory.
Advice for user
- Avoid positioning any objects and/or appliances that could be damaged by water leaks beneath the water
heater.
- Should you not use any water for an extended period of time, you should:
disconnect the appliance from the electrical supply by switching the external switch to
➣
"OFF";
turn off the plumbing circuit taps.
➣
- Hot water at above 50°C flowing out of the taps at the point of use could cause serious scalds or even death
from burns. Children, the disabled and the elderly are more exposed to the risk of burns. It is strictly forbidden
for the user to perform any routine or extraordinary maintenance.
To clean the external parts use a damp cloth soaked in soap and water.
Adjusting the temperature and activating the functions
The product is set to "Manual" by default, with a temperature set to 70 °C and the function "ECO EVO" is
active. In case of a power failure or if the product is switched off using the button ON/OFF (Ref. A), the last
temperature set remains saved.
Slight noise may occur during the heating phase due to the water being heated.
• For models equipped with user interface shown in figure 8:
Switch the appliance on by pressing the ON/OFF button (Ref. A). Set the desired temperature by selecting a
level between 40°C and 80°C using the " + " and " - " . buttons. During the heating phase, the LEDs (Ref. 1-5)
related to the temperature reached by the water remain on; the subsequent ones, until the temperature is
set, flash progressively. If the temperature drops, for example due to water being drawn, the heating is auto-
matically reactivated and the LEDs between the last one on (steady) and that related to the set temperature
start to flash progressively again.
• For models equipped with user interface shown in figure 9:
Switch the appliance on by pressing the ON/OFF button (Ref. A) During the heating phase, the lines on both
sides of the display (Ref. C) remain on.
On first installation, the display must be oriented according to the installation of the product. If vertical no
action is required; if horizontal, the display must be oriented accordingly by pressing the "MODE" + "ECO"
simultaneously for 5 seconds.
Setting- changing local time.
To change local time, when the machine is first switched on, the product automatically prompts you to set
the correct time; during subsequent use the "set" button must be held down for 3 seconds. To change current
time, turn the knob and press the "set" button to confirm. Repeat the operation to set minutes.
Programming mode (Manual, Program 1, Program 2, Program 1 and 2).
On each touch of the "Mode" button a different operating mode is selected (indicated by the corresponding
flashing writing: P1, P2, Man). The selection of the functions is cyclical and follows this order: P1, P2, P1 and
P2 together, manual, P1 new, etc. The programs "P1" and "P2" are set by default for the time bands 07:00
and 19:00 and at a temperature of 70 °C.
"Manual" mode (symbol "Man" on).
Allows the user to set the desired temperature simply by turning the knob until the desired temperature is
displayed (Ref. E) (the adjustment range is 40 °C - 80 °C) and in the display you can see the number of sho-
wers available based on the related on icons . By clicking the set button, the setting is saved. Both during
the temperature selection phase and in the heating phase you can display the waiting time (Ref. F) that the
product will take to reach the temperature (Ref. E).
The "Program 1" (writing "P1" on), "Program 2" (writing "P2" on) and "Program 1 and 2" (writing "P1" and
"P2" on) allow you to program up to two time bands of the day when you want to have hot water. Press the
"mode" button until the writing related to the desired program starts flashing. Now set the time at which hot
water is desired by turning the knob (select the time by 30 minutes increments). By pressing the "set" button,
the time is saved.
To set the water temperature to the desired level, turn the knob and press the "set" button to save the setting.
EN
25