6 - FURTHER DETAILS - ADVANCED MENU
The ADVANCED MENU allows the system to be further customised
by modifying parameters not accessible from the basic menu.
To access the ADVANCED menu, press the MENU key and hold it
down for 5 seconds.
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU.
PARAMETS
Use of PHOTO1 when starting from closed
SP.h.
0 = PHOTO1 is checked
1
1 = The gate starts even with PHOTO1 excited
Use of PHOTO2
Ph.2.
0 = Enabled during both opening and closing AP/CH
2
1 =Only enabled during opening AP
Photo-device test
0 = off
tP.h.
1 = PHOTO1 on
3
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
STOP input selection
n
0 = STOP contact (NC)
Ed.m.
4
1 = Resistive safety edge (8k2)
2 = Contact safety edge (NC)
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
iE.D.
5
1 = stops the automation (during both opening and
closure) and retreats from the obstacle
Edge test
tE.D.
6
0 = off
1 = on
LP.o.
Parcial opening
7
TP.C.
Time for automatic closure from parcial opening (0=off)
8
Flashing light output setup
0 = Steady
1 = Flashing
2 = Two-colour LED strip for barrier (MODE 1)
- gate closed steady red
- gate open LEDs off
- during opening flashing green
- during closing flashing red
- stopped not on limit switch flashing red
FP.r.
3 = two-colour LED strip for barrier (MODE 2)
9
- gate closed steady red
- gate open steady green
- during opening flashing green
- during closing flashing red
- stopped not on limit switch flashing red
N.B.: if this parameter is set as 2 or 3, the settings of
parameter .D. will be ignored.
If this parameter is set as 2 or 3, the flashing light and gate
open light outputs will be used for operation with the LED strip
tP.r.
10
Pre-flashing time (0 = off)
Courtesy light setup
0 = On at end of operation for time TCY
FC.Y.
11
1 = On if gate not closed + duration of TCY
2 = On if courtesy light timer (TCY) time not out
tC.Y.
Courtesy light on time
12
LEGENDA:
SL= sliding gate
BA= barrier
OH= up-and-over door
N.B. Some default functions/display items may vary with respect to
the type of motor selected.
DESCRIPTION
DEFAULT MIN
MAX
1
0
1
1
0
1
0
0
3
0
0
2
0
0
1
0
0
1
50
10
100
0
0
900
1 *
0
3
0
0
20
0
0
2
0
0
900
EN
UNIT
TYPE
SL/BA/
OH
SL/BA/
OH
SL/BA/
OH
SL/BA/
OH
SL/BA/
OH
SL/BA/
OH
%
SL
s
SL
SL/BA/
OH
SL/BA/
s
OH
SL/BA/
OH
SL/BA/
s
OH
27