Installation and User Manual
Image 7 Location for the connection box
2.11 Location the connection box for connection cable in the sauna room
A = Specified minimum safety clearance
1. Recommended location for the connection box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connection box
must be clear of obstacles. When installing the connection box to zones 2 or 3, refer to the instructions and
regulations of the local energy supplier.
2.12 Wiring diagram
1714-450-04
1714-600-04
1714-800-04
1714-900-04
Havanna D
A
KIUAS
Heater
Lämpövastukset, Värmeelement, Tennid,
Teho, Effekt
Heating elements, Heizeelement, Resistores
Input, Potencia
Térmicos, Éléments chauffants, Elementy
Leistung, Moc
Vöimsus,Wejscie
grzewcze,
Puissance
SEPC 93
kW
1500W
1,2,3
4,5
6,0
8,0
9,0
1 2 3 4 5 6
N
400V - 415V 3N~
Image 8 Wiring diagram
A
3.
1.
2.
ТЭНы,
230 V
SEPC 94 SEPC 95
SEPC 96
2000W
2670W
3000W
1,2,3
1,2,3
1,2,3
3
2
1
L1 L2 L3
354 SKS0 32 A
10