1.6 Electrical Installation

For connector overview and I/O connection (➜ # 148).

1.6.1 Important Notes

Only professional staff who are qualified in electrical engineering are allowed to install the
controller. Wires with color green with one or more yellow stripes must not be used other
than for protective earth (PE) wiring.
Excessively high external fusing will endanger cables and devices. The fusing of the 24 V
supply must be installed by the user, best values (➜ # 12).
It is permissible to use the setup software (KAS IDE) to alter the device settings. Any other
alterations will invalidate the warranty.

1.6.2 Guide to electrical installation

Install the PCMM electrical system as follows:
1. Select cables in accordance with IEC 60204 .
2. Install shielding and ground the PCMM.
3. Connect all interfaces according to the wiring diagrams in (➜ # 148).
14
Kollmorgen | kdn.kollmorgen.com | July 2019
Ground the mounting plate and CNC-GND of the control system.