LED screen
Press
to set and check
the operation data
Press `SET` to change the
parameter value
Parameter 0
Set the water-inlet temperature
in heating mode (15-40°C)
default setting: 27°C
Parameter 3
Set defrost cycle start-up
temperature (-30-0°C)
default setting: -6°C
Press the key to set the
Press the key to set the
time to turn on the unit
time to turn off the unit
Parameter 1
Set the water-inlet temperature
in cooling mode (8-28°C)
default setting: 27°C
Parameter 4
Set defrost cycle stop
temperature (0-30°C)
default setting: 13°C
Press`MODE` to change the
running mode
Press
to turn on and
turn off the unit
Press `CLOCK` to set
the time
Parameter 2
Total working time of
compressor after defrost
cycle
Parameter 5
Max. duration of defrost cycle
(0-15 min.)
default setting: 8 min.