Descargar Imprimir esta página

Montarbo M22A Manual De Instrucciones página 9

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

M22A / M44A
bi-amped, active stage monitors
Control and connection panel
3
4
5
Controls and connections are the same for both models.
1
IN: balanced input, fitted with a Neutrik Combo
which accepts both 3 pin XLR and jack plugs.
☛ See 'connectors' and 'connections' at pages 26 and 27.
2
OUT: balanced output, (in parallel with the input), using a 3 pin
XLR connector. It allows for easy parallel connection of other
M22A / M44A.
☛ See 'connectors' and 'connections' at pages 26 and 27.
3
MASTER LEVEL: it is the master volume control.
Adjusts the input levels of the 2 built-in power amplifiers
to adapt them to the output level of the mixer.
It also allows to adjust the speaker volume when this system
is used in parallel with others.
Typical operating setting is at maximum position.
The trademark Neutrik Combo
®
is property of Neutrik
6
4
connector
H.F. LEVEL: High frequencies level control.
®
Note: if you are using a Montarbo mixer (or any mixer
having an output level of 0dB), for optimum performance
it is advisable to set both the MASTER LEVEL and the H.F.
LEVEL controls fully clockwise (at their maximum settings).
5
POWER /0 - I: Mains power on/off switch.
6
Mains power cord socket (with built-in fuse).
Use only the factory supplied mains cable or a suitable
cable with a ground connection and marked with the
safety approvals valid in the country of use.
When installing make sure that it is easy to get to this
connector and to the mains plug.
FUSE REPLACEMENT
Service fuse
Spare fuse
1
2
9
ENGLISH

Publicidad

loading

Este manual también es adecuado para:

M44a