Maintenance

CARTRIDGE REPLACEMENT

- Turn off the water supply to the faucet .
- Unscrew the handle lever (1). Loosen the set screw (2) with the hex key and remove the handle body (3).
- Gently unscrew the decorative cap (4) and retaining nut (5).
- Pull the cartridge (6) out of the faucet body (7) and replace it with a new ceramic cartridge. Ensure new cartridge is seated properly
with the locating pins in appropriate place .
- Secure the cartridge in place using the retaining nut (5).
- Gently tighten the retaining nut (5) using a wrench. Do not overtighten.
- Reinstall the decorative cap (4). Slide the handle body (3) back onto the cartridge and make sure it rotates freely. Secure the handle
body (3) in place using the set screw (2) and reinstall the handle lever (1).
- Turn the water supply to the faucet back on .
- Operate the faucet to make sure everything works correctly and check for leaks .
Retaining Nut (5)
Cartridge (6)
Faucet
body (7)
Please contact cs@conglomkb .com or 1-877-333-0098 for further assistance .