4. ELECTRICAL CONNECTION

CAUTION: Before working, turn off the electricity at the main circuit breaker.
 The installation must be carried out in the rules of the art and meet the standards in
force in the country (NFC15-100 in France).
 The unit must be connected to a standard wall box placed at least 60 cm from the
floor.
 The appliance must not be connected to an outlet with a power plug.
 The appliance must be supplied through a residual current device (RCD) having a
rated residual operating current not exceeding 30 mA.
 The appliance must not be connected to the earth wire (yellow and green wire).
 Blue or light gray wire connect to Neutral (230V)
 Brown or red wire connect to Phase (230V)
 Black wire connect to pilot wire. Optional function to use in case of control by pilot
wire box (do not connect to ground).
 In the absence of pilot wire, insulate the bare end of the black wire to prevent
electrical contact with the other wires or ground.