EVENT: PEDESTRIAN DOOR LOCK RELEASE COMMAND FROM
SWITCHBOARD
Program the event by sending a pedestrian door lock release command from the switchboard (see paragraph
about events programming).
When the programming has been performed, the relay is activated each time a pedestrian door lock release
command is sent from the switchboard.
The position of dip-switches CODE and jumpers SCQ of special decoder is irrelevant for the
operation with pedestrian door lock release command from switchboard.
EVENT: DRIVEWAY DOOR LOCK RELEASE COMMAND FROM SWITCHBOARD
Program the event by sending a driveway door lock release command from the switchboard (see paragraph
about events programming).
When the programming has been performed, the relay is activated each time a driveway door lock release
command is sent from the switchboard.
The position of dip-switches CODE and jumpers SCQ of special decoder is irrelevant for the
operation with driveway door lock release command from switchboard.
EVENT: SPECIAL CODES COMMAND FROM CALL STATION OR
SWITCHBOARD
Program the event by sending a special code "SPEC" from a call station or from the switchboard that must
activate the special decoder relay (see paragraph about events programming). The device from which the
special code is sent can be a secondary call station in the column number "Column ID", a main call station
or a switchboard.
When the programming has been performed, the following events will occur:
•
Sending of special code "SPEC" from the switchboard activates the decoder.
•
Sending of special code "SPEC" from a main call station activates the decoder.
•
Sending of special code "SPEC" from a secondary call station activates the decoder, according to the
position of jumper SCQ:
–
Position Q: Sending of special code "SPEC" from any secondary call stations activates the decoder.
–
Position C or S: Sending of special code "SPEC" from any secondary call stations in the column
"Column ID" activates the decoder.
The position of special decoder dip-switches CODE is irrelevant for the operation with special
functions buttons.
CALL EVENT FROM CALLING STATION TO A USER IN THE SYSTEM
Program the event by calling a real user (*) from the calling station which will activate the special decoder
relay (see examples and summary table).
(*) The words "real user" means a correctly wired and operating apartment station.
A calling station may be a secondary calling station in column number "Column ID" or a main
calling station.
The apartment station of the called user must be working.
The position of the SCQ jumper will determine the following behaviour after programming for this event:
•
Position Q: call from a particular main calling station to any real user in the system will activate the
decoder.
To use position Q the event must be programmed from a main calling station.
EXAMPLE
Event programmed with call from main PE 1 to user 01 053.
All calls from main calling station 1 to any real user will activate the decoder.
DS1083-019D
15