Weekly Maintenance

Prepare a cleaning solution made of 4 parts water
1.
to 1 part white vinegar for cleaning the PILLAR.
Lift off the lid, reach down to the bttom of the
2.
tank and unscrew the demineralization cartridge,
installed directly over the water release port. Rinse
it well under the running water. Lift off the tank and
empty any remaining water from the tank and base,
noting cautions on the previous page.
Half fill the tank with the water and vinegar solu-
3.
tion, replace the lid and carefully swish the solution
around inside. Let the solution sit for 20 to 30 min-
utes. Empty the tank and use a soft cloth dampened
with the solution to wipe the tank out. Rinse the
tank very carefully with clear water. Do not leave
any cleaning solution residue in the tank.
Reinstall the demineralization cartridge by screwing
4.
it into the threads around the water release port.
Wipe the surfaces dry with a soft cloth.
NOTE: Replace the demineralization cartridge every 60 to
90 days of use. See replacement parts list on the next page.
CAUTION: Always pour water out of the tank AWAY from
air intake, to prevent damaging the unit. See the illustration
in the margin.
With the water tank set aside, clean the base with
5.
the same vinegar solution. Carefully pour the
solution into the basin portion of the base. Do not
allow water to enter the air intake. Let the solution
sit for 20 to 30 minutes. Using a soft toothbrush,
gently scrub the contours of the base. Gently clean
the nebulizer with the soft brush. Do not scratch the
nebulizer with a hard object.
Pour out the solution, away from the air intake, then
6.
rinse the water basin with fresh water and wipe out
thoroughly. Do not allow water or cleaning solution
to get into the controls.
Put a little vinegar/water solution on a soft, clean
7.
cloth and wipe down the outer surface.
Dry the unit with a soft, clean cloth.
8.
Reassemble by placing the tank on the base.
9.

Storage

1.
Clean the unit as outlined above. Dry out the unit
thoroughly.
2. Store in the original package, if available. Keep this
manual with unit. Take care that nothing heavy is
placed on top of the box.
3. Do not store the unit in an attic or other high-temp-
erature area, as damage will occur.
FOR HELP, CALL 1.800.547.3888 OR VISIT AIRCAREPRODUCTS.COM
FLOAT
AIR INTAKE
9
USE WHITE VINEGAR
FOR CLEANING
BASE COMPONENTS
POUR WATER
AWAY FROM
AIR INTAKE
NEBULIZER