6 - APPLIANCE USE
Each time one of the buttons is pressed, the appliance emits a "beep".
"AUTOMATIC" mode
a. Press the power button (5a); the appliance starts in "Automatic" mode ("AUTO" led turned
on) and the fan is at the minimum speed ("I" led turned on).
b. The appliance detects air quantity in the environment and the display (10) shows the quantity
of impurities in air (
c. If desired, it is possible to manually set a different fan speed by pressing "MODE" button
(5b).
When selecting night speed " ", the fan works at the minimum speed ("I") and the led "5c"
turns off.
"TIMER" mode
a. Press the power button (5a); the appliance starts in "Automatic" mode ("AUTO" led turned
on) and the fan is at the minimum speed ("I" led turned on).
b. Press button
• 1h > 2h > 4h > 8h > Function turned off.
The appliance works for the set time and it automatically turns off.
If "Night" mode has been selected .....
... press "Timer" (5e), the appliance exits from "Night" mode and it automatically goes in
"AUTO" mode,
... turn the UV light on (button "5d"), the appliance exits from "Night" mode and it automatically
goes in "AUTO" mode.
"NIGHT" mode
a. Press the power button (5a); the appliance starts in "Automatic" mode ("AUTO" led turned
on) and the fan is at the minimum speed ("I" led turned on).
b. Press button"MODE" (5a) four times to select the "Night" function; the related led " " turns
on and the fan is at the minimum speed ("I" led turned on).
If "Night" mode has been selected .....
... press "Timer" (5e), the appliance exits from "Night" mode and it automatically goes in
"AUTO" mode,
... turn the UV light on (button "5d"), the appliance exits from "Night" mode and it automatically
goes in "AUTO" mode.
To set the timer or to turn the UV light on in "Night" mode, it is necessary to set the functioning
time first (button "5e") and/or to turn the UV light on (button "5d"), then to press the button (5b)
until "Night" mode is selected.
Appliance switching off
a. Press the power button (5a); all the leds turn off.
) and the value of reference "PM 2.5" (fine particulates).
(5e) to select the desired functioning time; the related led (5e) turns on.
EN - 8