Response time of the outputs:
1-channel operation < 100 ms @ 40 kHz
< 350 ms @ 65 kHz
2-channel operation < 150 ms @ 40 kHz
< 600 ms @ 65 kHz
10.4

Timer

Seconds
Minutes
Hours
h.min.s
Min. time measurable
Measuring error
Response time of the outputs:
Relays
Optocoupler
10.5

Signal and Control inputs

SELV circuits, reinforced / double insulation
Polarity:
programmable NPN/PNP
for all inputs in common
Input resistance
5 kΩ
Pulse shape
any
Switching level with AC supply:
HTL level
Low:
High:
4-30 V level
Low:
High:
Switching level with DC supply:
HTL level
Low:
High:
4-30 V level
Low:
High:
Minimum pulse length of the Reset input: 1 ms
Minimum pulse length of the Control inputs:10 ms
10.6

Outputs

Output 1
Relay with make contact
Prescribed fuse:
3A
programmable as NC or NO
Switching voltage
max. 250 VAC/ 110 VDC
Switching current
max. 3 A AC/ V DC
min. 30 mA DC
Switching capacity
max. 750 VA / 90 W
The maximum values shall in no case be
exceeded!
Mechanical service life (switching cycles)
N° of switching cycles at 3 A/ 250 V AC
N° of switching cycles at 3 A/ 30 V DC
or NPN optocoupler
Switching capacity
U
for IC = 10 mA:
CESAT
U
for IC = 5 mA:
CESAT
www.kuebler.com
0.001 s ... 999 999 s
0.001 min ... 999 999 min
0.001 h .. 999 999 h
00h.00min.01s ...
99h.59min.59s
500µs
< 50 ppm
< 13 ms
< 1 ms
0 ... 4 VDC
12 ... 30 VDC
0 ... 2VDC
3,5 ... 30 VDC
0 ... 0,2 x UB
0,6 x UB ... 30 VDC
0 ... 2 VDC
3,5 ... 30 VDC
2x10
1x10
1x10
30 VDC/10 mA
max. 2.0 V
max. 0.4 V
Output 2
Relay with changeover contact
Prescribed fuse:
Switching voltage
Switching current
Switching capacity
The maximum values shall in no case be
exceeded!
Mechanical service life (switching cycles)
N° of switching cycles at 3 A/ 250 V AC
N° of switching cycles at 3 A/ 30 V DC
or NPN optocoupler
Switching capacity
U
for IC = 10 mA:
CESAT
U
for IC = 5 mA:
CESAT
10.7

Supply voltage

AC supply:
DC supply:
10.8

Sensor supply voltage

(Voltage output for external sensors)
SELV circuits, reinforced / double insulation
for AC supply:
for DC supply:
10.9

Climatic Conditions

Operating temperature: -20°C .. +65°C
Storage temperature:
Relative humidity: RH. 93% at +40°C,
Altitude:

10.10 EMC

Noise immunity:
7
5
5
Noise emission:
3A
max. 250 VAC/ 150 VDC
max. 3 A AC/ A DC
min. 30 mA DC
max. 750 VA/ 90 W
20x10
30 V DC/10 mA
max. 2.0 V
max. 0.4 V
100 ... 240 V AC / max. 9 VA
50/ 60 Hz, Tolerance ± 10%
ext. fuse protection: T 0.1 A
24 VAC +/- 10% / max. 6 VA
50 / 60 Hz
ext. fuse protection: T 0,315 A
10 ... 30 V DC/ max. 4.5 W
reverse polarity protection
SELV, CLASS II (Limited
Power Source)
ext. fuse protection T 0.2 A
24 V DC ±15%, 80 mA
max. 80 mA, external voltage
supply is connected through
-25°C .. +75°C
non-condensing
to 2000 m
EN61000-6-2
with shielded signal and
control cables
EN55011 Class B
Page 19