Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SW CUBE 12V

7.3 - ERRORS

In case of a problem, the device shuts down and the display will show one error message from the following list.
Message
Description
Battery power
(The
E1  
decreased below the set threshold.)
Power overload from the cooling fan
E2  
(The cooling fan overloads the board beyond
the allowed limit. Possible cause: short circuit or
something is blocking the fan from rotating.)
Blocked compressor
(The rotor is blocked or the pressure in the
E3  
cooling circuit is too high.)
Minimum compressor rotation speed
(If the cooling circuit is overloaded, the
E4  
compressor is unable to maintain minimum
rotation speed.)
High temperature in the control board
(If the cooling circuit is overloaded or if the
E5  
surrounding temperature is too high, the control
board signals this issue.)
Communication error
E6  
(No communication between the display and the
control board.)
Temperature probe
E7  
(If the probe has short circuited or has become
disconnected, the device stops working.)
Power overload from the condenser fan
E9  
(The cooling fan overloads the board beyond
the allowed limit. Possible cause: short circuit or
something is blocking the fan from rotating.)
SW_CUBE_12V_20-02-2019
battery-saver
has
activated.
Troubleshooting
Power
Start the vehicle in order to recharge the
battery.
Take the device to an authorised dealer.
The presence of E3   –   E4   –  
indicate
a
malfunction,
management procedure for the compressor by
the electronic board. Only if the code continues
to be displayed contact an authorized dealer.
Take the device to an authorised dealer.
40
E5
codes do not
but
is
a
normal

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sleeping well cube

Tabla de contenido