3 - 3200 NT PROGRAMMATION
As soon as programmation mode is entered, all parameters can be displayed or set to suit your
needs. Depending on the current programming, some functions will not be displayed or will not
be changeable.
Programmation access
The valve is in service
Set the time of day to 12:01. Push simultaneously the
program L.E.D will light up.
Use the
and
buttons to set the values of the parameters.
To go from one display to another, press
Valve type
This parameter allows chosing the valve model used with the 3200NT electronics.
Use the
and
to change the valve model.
Ex.: 2850 valve
Regeneration type
This parameter allows setting the regeneration type. The availability depends on the type of
valve chosen in the previous stage.
Ex.: Downflow regeneration
Upflow regeneration
System type
This parameter allows indicating the system type in which the valve will be used. Use the
and
to select. Here are the following options:
- system #4 – timeclock
The electronics will establish that a regeneration is requested when the set amount of days in
the calendar forcing is reached. The valve will regenerate at a preset time.
- system #4 – meter immediate
The electronics will establish that a regeneration is requested when the volume of soft water
reaches 0. The regeneration starts immediately.
- system #4 – meter delayed
The electronics will establish that a regeneration is requested when the volume of soft water
reaches the reserve capacity. The regeneration will start at a set time.
- system #5 – multiplex meter immediate (interlock)
It allows doing a system going from 2 to 4 valves. Each valve has got its own meter; all the valves
are in service. Only one unit will be regenerating at a time. The valve that will have its softened
water level down to zero will regenerate immediately only if no other valve is in regeneration.
- system #6 – multiplex meter immediate (serial regeneration)
It allows doing a system going from 2 to 4 valves. All the valves are in service and there is only
one meter for the whole system. As soon as the volume of soft water reaches 0, the electronics
will trigger a regeneration of the first unit. As soon as the first unit has finished regeneration, the
second unit will start; the same cycle will apply up to 4 valves.
- system #7 – duplex meter immediate (alternated)
It allows doing a duplex. Only one valve will be in service while the other will be regenerating or
in standby. Only one meter will be connected to the lead valve [LEAD]. When the volume of water
will reach zero on the unit in service, a regeneration will start. The unit in standby will then go in
service. The unit that was in standby will go in service; the unit that was in service goes in
standby and then regenerates.
and
.
buttons for 5 seconds, the
[ 2 8 5 0 ]
[
dF]
[UFbF]
[
4tc]
[
4FI]
[ 4Fd]
[
5FI]
[
6FI]
[
7FI]