3.5. Installation tests
Make sure that the pool is still and that your immersion detector is monitoring (green indicator light
flashing). If such is not the case, move the magnet over the swimmer symbol:
If in spite of this, the indicator light does not switch to green, this means that the pool is not still
enough. You must wait for your pool to be still before carrying out the tests.
You must wait for about ten minutes without handling the device in any way, and
with no disturbance in the pool, for your immersion detector to analyze its
environment and become stable (green indicator light). It is only after this time
that you will be able to perform the tests described below.
Prepare a 6 kg weight by tying together four 1.5 liter water bottles, as shown below:
1
x1
Your immersion detector is in
monitoring mode (green indicator light flashing)
To make it easier for you to recover the 6 kg
weight in the pool, we recommend that you tie a
rope about 2 meters long around the neck of one
of the bottles.
2
10 mn
Filtering working for 10 minutes,
your immersion detector is monitoring (green
indicator light flashing) and must not set off the
alarm.