Astralpool BASIC Manual De Instalación página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3
10 mn
Filtering
and
robot
working for 10 minutes, your immersion
detector is monitoring (green indicator light
flashing) and must not set off the alarm..
5
x5
The siren must go of 12 seconds
maximum after the fall. Stop the siren using
the magnet.
You must always perform additional fall tests at different locations in the pool (including
steps) as per the procedure described above.
After each fall, allow your immersion detector to be automatically reactivated before the
next fall. Depending on wind and pool disturbance conditions, this reactivation may take
about ten minutes.
If one of these tests fails:
I
Look up item 5.
I
Contact your retailer for advice.
Check with the AstralPool After Sales Service at +34.93.713.63.44.
I
I
Send a letter to the AstralPool technical department, clearly describing your problem, and leaving
your details at the following address:
cleaner
AstralPool SAU
Avda Francesc Macia, 38 Planta 18
08208 Sabadell – Spain
16
4
With the filtering system and robot cleaner
working, drop the 6 kg weight from the top of
the coping, from the point furthest away from
your immersion detector.
6
x1
Wait for the automatic restart
(green indicator light flashing). This may
take about ten minutes.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

37058

Tabla de contenido