Advanced Test Products
CARE AND MAINTENANCE OF YOUR
A filter must always be used and should be replaced frequently. Failure to use a filter
CAUTION : To prevent personal injury, disconnect the unit from the power supply before
will invalidate your warranty. The use of a filter will greatly reduce the risk of damage to
performing maintenance.
your RG6-E by preventing foreign material from entering the unit.
Installation of the Filter and Filter / Drier
Burned-out System
1.
Special consideration for filtration must be given when you know the machine you are
servicing has "burned out". We recommend the use of two size 162 filter driers, in line,
to be used for that job and that job only. We also recommend that a clean filter be used
for every service job. Each filter should be labeled and used exclusively for one type of
refrigerant only.
Do not use this unit in the vicinity of spilled or open containers of gasoline or other
Burned-out System
combustible liquids
Avoid the use of extension cords. If you must use an extension cord it should be a
minimum of 14 AWG and no longer than 7,5 m (25 ft). Not using an extension cord will
refrigerant and refrigerant oil to purge any foreign substances left in the unit.
greatly reduce the risk of fire.
Storage
Always purge the unit of any refrigerant left after completing a service job. Refrigerant
left in the machine can expand and may cause damage to components.
If the unit is to be stored or not used for any length of time, we recommend that it be
in storage for a long period of time.
completely evacuated of any residual refrigerant and purged with dry nitrogen.
Whenever you perform any type of maintenance work on your RG6-E, insure that it is
disconnected from the power supply before you begin.
M
RG6-E
AINTENANCE
Inlet
Filter
Fitting
Screen
14
13
RG6-E
Filter /Drier
p/n 100343