Installation, use and maintenance
Installation
example
1
2
3
air
line
Fixing the
dispensing
system
14
/112
The diagram below provides an example of a possible
configuration for the installation of the "PIUSI P 3.5 - PIUSI P 5.5"
system. For support in designing a system, you need to consult
qualified personnel.
1
Bleed ball valve
¦
(mandatory)
2
Filter
¦
3
Pressure regulator with pressure gauge
¦
4
Lubricator
¦
5
Safety valve
¦
6
Pump casing
¦
7
Thermal safety device
¦
8
Drain valve
¦
(mandatory)
1
4
5
Fix the pump casing securely to the
wall (ST version) using a suitable
bracket, or fix it to the lid of the
drum (940 version), inserting it
completely with pick-up hose and
tightening the fixing screws. Then
connect the pump to the air line,
making sure that the components
shown in the figure are present.
(mandatory)
1
6
7
WARNING
The air accessories must be fitted
with suitable support brackets. The
pump unit fittings can be damaged
by the weight of the accessories in
the line.
8
user
M0352 rev.01 EN