3.9 Condensation
The air drawn into the heat pump is strongly cooled by the operation of the heat pump for heating the pool
water, which may cause condensation on the fins of the evaporator. The amount of condensation may be as
much as several litres per hour at high relative humidity. This is sometimes mistakenly regarded as a water
leak.
4. Accessories

4.1 Accessories list

Anti-vibration base, 4 pcs
Winter cover, 1pc

4.2 Accessories Installation

Draining jet, 2 pcs
Water drainage pipes, 2 pcs
15
Anti-vibration bases
1. Take out 4 Anti-vibration bases
2. Put them one by one on the
bottom of machine like the picture.