Parameter
1
2
3
4
5
6
7
A
L
Recover to Factory default setting
Long press
and
and then back to "OFF".
Meaning
To set the entering water
temp. under heating mode
Entry into defrosting time
period
Terms of Entry defrosting
function
Terms of Exit defrosting
Time of Exit defrosting
Mode: 0 Heat
Mode selection of Electronic
expansion valve
Manual adjustment steps of
electronic expansion valve
Entering water temperature
calibration
simultaneously in 10 second to recover to factory default setting ,it will display "0000"
Range
Default
15-42°C
28°C
30-90MIN
40MIN
-30°C to0°C
-7°C
2 to 30°C
20°C
1 to 12MIN
12MIN
0
0
0-1
1(auto)
18-94
70
-9.9-9.9
0
21
Remarks
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Not adjustable
Adjustable
Adjustable
Adjustable