EN50131 Compliant Installations
1. The TL2803G(R)-EU, 3G2080(R)-EU module is monitored
by the control panel and it is programmed via the programming
menu (* 8, section [851] in the control panel. The interface is
connected to the PC-Link bus as shown in the diagram included
in this manual.
2. The Ethernet port is protected against surge transients up to
2.5kV and both Ethernet port and GPRS/3G Cellular path are
immune to conducted and radiated RF fields with levels up to
10V/m as tested per EN50130-4 Standard.
3. The TL2803G(R)-EU, 3G2080(R)-EU module conforms with
radiated emissions levels for Class B equipment as per standards
EN61000-6-3/EN55022/CISPR22.
4. The TL2803G(R)-EU, 3G2080(R)-EU module uses AES128
encryption and heartbeat supervision for both Ethernet and
GPRS/3G Cellular communication paths and it meets security
Toronto, Canadá
Las marcas comerciales, logotipos y marcas de servicio que aparecen en este documento están registradas en los Estados Unidos (u
otros países). Cualquier mal uso de las marcas está estrictamente prohibido y Tyco Security Products hará cumplir agresivamente sus
derechos de propiedad intelectual con el mayor peso de la ley, incluida la prosecución de causa penal cuando sea necesario. Todas las
marcas comerciales que no son propiedad de Tyco Security Products son propiedad de sus respectivos dueños y se utilizan con permiso
o son permitidas bajo las leyes aplicables.
Los productos y sus especificaciones están sujetos a cambio sin previo aviso. El producto real puede variar a la imagen mostrada. No
todos los productos incluyen todas las prestaciones. La disponibilidad varía según el país; póngase en contacto con su distribuidor.
©2015 Tyco Security Products. Todos los derechos reservados.
www.dsc.com
Soporte técnico: 1-800-387-3630 (CA, US), 905-760-3000
◆
◆
levels S2 as per EN50136-2-1 (EN50131-1). It also uses
authentication for each message exchanged with the compatible
receiver equipment at ARC and it meets level I2 for information
security.
5. The TL2803G(R)-EU module has two communication paths:
Ethernet 10/100BaseT and GPRS/3G Cellular communication
path that can be used in a redundant (parallel) mode or back-up
mode configuration based on selecting the appropriate option in
the programming section [851][005]. The 3G2080(R)-EU
module has only one communication path:GPRS/3G Cellular
communication path using 900/1800/2100MHz Public Cellular
Network.
TL2803GR-EU, TL2803G-EU, 3G2080R-EU, 3G2080-EU have
been certified by Telefication in accordance with EN50131-1
requirements for Grade 2, Class II and ATS Class 3,4,5.