Type Code Breakdown - Balluff BTL5-A/C/E/G-M-P-S32/KA Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BTL5-A/C/E/G _ _ -M _ _ _ _ -P-S32/KA _ _
Micropulse Transducer in a Profile Housing
9

Type code breakdown

Micropulse transducer
Interface:
A = Analog interface, voltage output 0...10 V/10...0 V
C = Analog interface, current output 0...20 mA/20...0 mA
E = Analog interface, current output 4...20 mA/20...4 mA
G = Analog interface, voltage output -10...10 V/10...-10 V
Supply voltage:
1 = 24 V DC
2 = ±15 V DC
Output gradient:
0 = Rising: only C and E (e.g. C_0 = 0...20 mA)
1 = Rising and falling: only A and G (e.g. A_1 = 10...0 V and 0...10 V)
7 = Falling: only C and E (e.g. C_7 = 20...0 mA)
Nominal stroke (4-digit):
M0500 = Metric specification in mm, nominal length 500 mm
Construction:
P = Profile housing
Electrical connection:
S32 =
8-pin, M16 plug per IEC 130-9
KA05 = Cable, 5 m
www.balluff.com
BTL5 - A 1 1 - M0500 - P - S32
english
15

Publicidad

Tabla de contenido
loading

Tabla de contenido