Startup; Starting Up The System; Operating Notes - Balluff BTL7-V50T-M-P-C003 Manual De Instrucciones

Ocultar thumbs Ver también para BTL7-V50T-M-P-C003:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BTL7-V50T-M _ _ _ _ -P-C003
Micropulse Transducer in a Profile Housing
5

Startup

5.1

Starting up the system

DANGER
Uncontrolled system movement
When starting up, if the position measuring system is part
of a closed loop system whose parameters have not yet
been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
and readjust the transducer, if necessary.
Check for the correct values at the null point
and end point, especially after replacing the
transducer or after repair by the manufacturer.
5.2

Operating notes

Check the function of the position measuring system
and all associated components on a regular basis.
Take the position measuring system out of operation
whenever there is a malfunction.
Secure the system against unauthorized use.
www.balluff.com
english
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl7-v50d-m -p-c003 serie

Tabla de contenido